Tech Support > Computer Hardware > Routers > Coil error on Catalyst 6500
Coil error on Catalyst 6500
Posted by Jorpargar on July 21st, 2003


Hi all:

I have a Catalyst 6509 witch WS-6348-RJ-45 cards. In last weeks I
had several problems witch switches. In log messages apears this error:

%SYS-3-SYS_LCPERR3:Module 7: Coil Pb Rx Underflow Error - Port #5:
%SYS-0-SYS_LCPERR0:Module 7: Coil Pb Rx Parity Error - Port #5:

And different number ports.

What is happen?

TIA
Jorge

Posted by Andrey Tarasov on July 21st, 2003


Hello, Jorpargar!
You wrote on Mon, 21 Jul 2003 10:50:45 +0200:

J> I have a Catalyst 6509 witch WS-6348-RJ-45 cards. In last weeks I had
J> several problems witch switches. In log messages apears this error:

J> %SYS-3-SYS_LCPERR3:Module 7: Coil Pb Rx Underflow Error - Port #5:
J> %SYS-0-SYS_LCPERR0:Module 7: Coil Pb Rx Parity Error - Port #5:

J> And different number ports.

J> What is happen?

Error Message SYS-3-SYS_LCPERR3:Module [dec]: Coil Pb Tx Underflow Error -
Port #dec]



Explanation This message indicates an underflow in the port ASIC transmit
buffer. The first [dec] is the module number. The second [dec] is the ASIC port
number.

Recommended Action If the error is limited to a single module, replace the
module. If the error occurs several times, contact your technical support
representative.



Error Message SYS-0-SYS_LCPERR0:Module [dec]: Coil Pb Rx Parity Error - Port
#[dec]

Explanation This message indicates an error in the port ASIC. The first [dec]
is the module number. The second [dec] is the ASIC port number.

Recommended Action Replace the module if the error occurs several times, or
contact your technical support representative.

With best regards,
Andrey.