- Failed HD Mirror
- Posted by tlc on July 26th, 2007
Hello,
I am running 2003 Server in a server with 6 SCSI hard disks. I have a
software array of 2 O/S mirrored, 4 data Raid 5. SCSI disk 0 had failed with
bad blocks. Originally, I could not get it to boot, missing or corrupt
c/windows/sys32/config/system. Corrected that and booted into O/S. Mirrored
disks appear as Online w/errors. I need to replace the drive. I tried to
remove the mirror from Disk 0, however, I get an error :Logical Disk Manager,
operation failed to complete. The server is running for now, but I need to
replace this drive. Can someone help.
Thanks,
- Posted by Andrew Sword [MVP] on July 27th, 2007
Try this link
http://technet2.microsoft.com/window....mspx?mfr=true
"tlc" <tlc@discussions.microsoft.com> wrote in message
news:F3B3E3CF-63E4-4AEF-866F-1B35C1DAE8B2@microsoft.com...
- Posted by tlc on July 27th, 2007
Andrew,
My only concern is that the system disk is the drive that is bad. If I
understand what I am reading, if I break the mirror, the c: drive letter will
go to the disk that is not the book disk. Will this keep me from being able
to boot the server?
Tisa
"Andrew Sword [MVP]" wrote:
- Drive 0 in mirror failed (Windows Server) by Graham Coffer
- URGENT= CRM 1.2 to CRM 3.0 Upgrade failed - Microsoft CRM 1.2 database export failed (Windows CRM) by BizWorld
- CRM Server 3.0 setup SHGETFolder Path failed failed (Windows CRM) by sozden55@yahoo.com
- SP2 installation failed: Failed to install Catalog Files (Microsoft Windows) by Dmitry Duginov